With glass fibre protection braiding
Possesses insulating properties after combustion due to remaining SiO2 ash on the conductor
Areas with high ambient temperatures where conventional core insulation materials will embrittle after a short while. Typical fields of application
– Control cabinet manufacturing
– Appliances and apparatus engineering
– Electric motor industry
– Sauna/solarium construction
– Thermal and heating elements
– Lighting technology
– Ventilator engineering
– Air-conditioning technology
– Furnace construction
– Polymer processing
– Generator and transformer manufacturing
Halogen-free according to IEC 60754-1(amount of halogen acid gas)
Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
Flame-retardant according IEC 60332-1-2. Resistant to a multitude of oils, alcohols, vegetable and animal fats and chemical substances Adequate ventilation must be ensured, since the mechanical properties of silicone cables decrease from +100°C in the absence of air
Fine-wire, tinned-copper conductor
Silicone-based insulation
Impregnated glass fibre braiding white, with natural glass fibre braiding
Classification ETIM 5: ETIM 5.0 Class-ID: EC000993, ETIM 5.0 Class-Description: Single core cable
Classification ETIM 6: ETIM 6.0 Class-ID: EC000993, ETIM 6.0 Class-Description: Single core cable
Conductor stranding: Fine wire acc. to VDE 0295, class 5 / IEC 60228 class 5 from 0.5mm²
Minimum bending radius: Fixed installation: 6 x core diameter
One bend at end of core:3 x cable diameter
Nominal voltage: Version SiF/GL / SiZ:
U0/U 300/500 V
Version FZLSi:10 kV
Test voltage: Version SiF/GL / SiZ:
2000 V
Version FZLSi:20 kV
Temperature range: -50 °C to +180 °C
(adequate ventilation required)
Short-term: +200°C
Note: Please follow manufacturer datasheets and guidelines for cable usage and installation.